Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Rev. bras. ginecol. obstet ; 42(2): 81-89, Feb. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1098853

RESUMO

Abstract Objective The present study aimed to analyze cardiac autonomic modulation via spectral and symbolic analysis of heart rate variability (HRV) in women with polycystic ovary syndrome (PCOS) who were subjected to two consecutive tilt tests. Methods A total of 64 women were selected and divided into 2 groups: control (without PCOS), and PCOS. Concentrations of follicle-stimulating hormone, luteinizing hormone, prolactin, estradiol, homocysteine, sex hormone-binding globulin, thyroid stimulating hormone, fasting insulin, testosterone, androstenedione, and 17-hydroxyprogesterone levels, triglycerides, free androgen index (FAI), and homeostasis assessment model (HOMA-IR) were assessed. Cardiac autonomic modulation was evaluated by spectral and symbolic analyses during two consecutive tilt tests (two moments) and supine moments before, between and after (three moments) the tilt tests. Results Women with PCOS had higher fasting insulin, HOMA-IR indexes, testosterone and FAI. Additionally, we observed that the PCOS group had greater sympathetic autonomic cardiac modulation in supine 2, tilt 1, and supine 3 moments compared with controls. Conclusion Women with PCOS had higher autonomic sympathetic cardiac modulation even after a second tilt test. No adaptation to this provocative test was observed. Spectral analysis was more sensitive for identifying differences between groups than the symbolic analysis.


Resumo Objetivo O presente estudo teve como objetivo analisar a modulação autonômica cardíaca por análise espectral e simbólica da variabilidade da frequência cardíaca (VFC) em mulheres com síndrome dos ovários policísticos (SOP) que foram submetidas a dois testes consecutivos de inclinação. Métodos Um total de 64 mulheres foram selecionadas e divididas em 2 grupos: controle (sem SOP) e SOP. Concentrações de hormônio folículo-estimulante, hormônio luteinizante, prolactina, estradiol, homocisteína, globulina de ligação a hormônios sexuais, hormônio estimulante da tireóide, insulina em jejum, testosterona e androstenediona e níveis de 17-hidroxiprogesterona, triglicerídeos, índice de andrógeno livre (FAI) e homeostase modelo de avaliação (HOMA-IR) foram avaliados. A modulação autonômica cardíaca foi avaliada por análises espectrais e simbólicas durante dois testes de inclinação consecutivos (dois momentos) e momentos supinos antes, entre e após (três momentos) os testes de inclinação. Resultados Mulheres com SOP apresentaram insulina em jejuM, índices HOMA-IR, testosterona e FAI mais altos. Além disso, observamos que o grupo PCOS apresentou maior modulação cardíaca autonômica simpática nos momentos supino 2, inclinado 1 e supino 3 em comparação aos controles. Conclusão Mulheres com SOP apresentaram modulação cardíaca simpática autonômica mais alta mesmo após um segundo teste de inclinação. Nenhuma adaptação a esse teste provocativo foi observada. A análise espectral foi mais sensível para identificar diferenças entre os grupos do que a análise simbólica.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Adulto Jovem , Arritmias Cardíacas/fisiopatologia , Síndrome do Ovário Policístico/fisiopatologia , Arritmias Cardíacas/complicações , Síndrome do Ovário Policístico/complicações , Síndrome do Ovário Policístico/sangue , Síndrome do Ovário Policístico/diagnóstico por imagem , Hormônio Luteinizante/sangue , Estudos de Casos e Controles , Teste da Mesa Inclinada , Hormônio Foliculoestimulante/sangue
2.
Rev. bras. med. esporte ; 23(3): 208-212, May-June 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-898971

RESUMO

RESUMO Introdução: A variabilidade da frequência cardíaca (VFC) tem sido considerada um mecanismo de modulação do sistema nervoso autônomo. A diminuição da VFC pode estar associada à síndrome metabólica (SM). Objetivo: Comparar a VFC e variáveis de saúde em indivíduos com e sem SM. Métodos: Cento e dezenove participantes foram divididos em dois grupos: sem SM (SSM, n = 68) e com SM (CSM, n = 51). Foi avaliada a análise espectral da VFC em repouso, durante teste cardiopulmonar de exercício (TCPE) e na recuperação em bandas de baixa frequência (LF = 0,04-0,15 Hz), alta frequência (HF = 0,15-0,4 Hz) e razão LF/HF. Adicionalmente, a frequência cardíaca (FC) de repouso (FCrep), FC máxima (FCmáx), pressão arterial sistólica (PAS) e diastólica (PAD), glicemia, perfil lipídico, consumo de oxigênio pico (VO2pico) e composição corporal foram avaliados. Resultados: A FCrep e o VO2pico não apresentaram diferenças entre o CSM e o SSM (73,3 ± 9,1 vs. 70,1 ± 11,0 bpm) (26,8 ± 4,6 vs. 28,1 ± 6,6 ml.kg-1.min-1), respectivamente. A VFC foi similar entre os grupos nos diferentes momentos analisados. A glicemia (99,8 ± 22,5 vs. 87,6 ± 8,6 mg/dl) foi superior no CSM comparado ao SSM. Os valores de triglicérides (159,5 ± 68,8 vs. 89,2 ± 34,3 mg/dl) e VLDL-c (31,9 ± 13,8 vs. 17,8 ± 6,9 mg/dl) foram superiores no CSM comparado ao SSM. O HDL-c (40,7 ± 11,5 vs. 49,3 ± 9,8 mg/dl) foi menor no CSM comparado ao SSM. O IMC (33,1 ± 4,7 vs. 30,8 ± 3,8 Kg/m²) foi superior no CSM comparado ao SSM. A PAS (128,6 ± 12,9 vs. 119,5 ± 11,3 mmHg) e a PAD (77,2 ± 10,5 vs. 72,9 ± 8,1 mmHg) foram superiores no CSM comparado ao SSM, p < 0,05. Conclusão: Os resultados sugerem que a presença de SM não é suficiente para provocar alterações nos índices de VFC em repouso, durante teste cardiopulmonar de exercício (TCPE) e na recuperação quando os pacientes são comparados a indivíduos sem a doença.


ABSTRACT Introduction: Heart rate variability (HRV) has been considered a modulation mechanism of the autonomic nervous system. The reduction of HRV may be associated with metabolic syndrome (MS). Objective: To compare the HRV and health variables in individuals with and without MS. Methods: One hundred and nineteen participants were divided into two groups: without MS (WOMS, n=68) and with MS (WMS, n=51). We evaluated the spectral analysis of HRV at rest, during cardiopulmo-nary exercise testing (CPET) and recovery in low frequency bands (LF = 0.04-0.15 Hz), high frequency (HF = 0.15-0.4 Hz) and LF/HF ratio. Resting heart rate (HRres), maximum heart rate (HRmax), systolic blood pressure (SBP) and diastolic (DBP), blood glucose, lipid profile, peak oxygen consumption (VO2peak) and body composition were also evaluated. Results: There were no differences between HRres and VO2peak between the WMS and WOMS groups (73.3±9.1 vs. 70.1±11.0 bpm), (26.8±4.6 vs. 28.1±6.6 ml.kg-1.min-1), respectively. HRV was similar between the groups at the different moments analyzed. The blood glucose levels (99.8±22.5 vs. 87.6±8.6 mg/dl) were higher in WMS compared to WOMS. Triglyceride values (159.5±68.8 vs. 89.2±34.3 mg/dl) and VLDL-c (31.9±13.8 vs. 17.8±6.9 mg/dl) were higher in WMS compared to WOMS. HDL-c (40.7±11.5 vs. 49.3±9.8 mg/dl) was lower in WMS compared to WOMS. BMI (33.1±4.7 vs. 30.8±3.8 kg/m²) was higher in WMS compared to WOMS. The SBP (128.6±12.9 vs. 119.5±11.3 mmHg) and DBP (77.2±10.5 vs. 72.9± 8.1mmHg) were higher in WMS com-pared to WOMS, p<0.05. Conclusion: The results suggest that the presence of MS is not sufficient to induce changes in HRV at rest, during cardiopulmonary exercise test (CPET), and in recovery when patients are compared to healthy individuals.


RESUMEN Introducción: La variabilidad de la frecuencia cardiaca (VFC) ha sido considerada como un mecanismo de modulación del sistema nervioso autónomo. La disminución de VFC puede estar asociada con el síndrome metabólico (SM). Objetivo: Comparar la VFC y variables de salud en individuos con y sin SM. Métodos: Ciento diecinueve sujetos se dividieron en dos grupos: sin SM (SSM, n = 68) y con SM (CSM, n = 51). Se evaluó el análisis espectral de la VFC en reposo durante las pruebas de ejercicio cardiopulmonar (PECP) y la recuperación en banda de baja frecuencia (LF = 0,04-0,15 Hz), alta frecuencia (HF = 0,15-0,4 Hz) y la relación LF/HF. Además, se evaluaron la frecuencia cardiaca en reposo (FCrep), FC máxima (FCmáx), presión arterial sistólica (PAS) y diastólica (PAD), glicemia, perfil lipídico, consumo pico de oxígeno (VO2pico) y composición corporal. Resultados: FCrep y VO2pico no mostraron diferencias entre CSM y SSM (73,3 ± 9,1 vs. 70,1 ± 11,0 bpm) (26,8 ± 4,6 vs. 28,1 ± 6,6 ml.kg-1.min-1), respectivamente. La VFC fue similar entre los grupos en diferentes momentos analizados. La glicemia (99,8 ± 22,5 vs. 87,6 ± 8,6 mg/dl) fue mayor en CSM en comparación con SSM. Los valores de triglicéridos (159,5 ± 68,8 vs. 89,2 ± 34,3 mg/dl) y VLDL-C (31,9 ± 13,8 vs. 17,8 ± 6,9 mg/dl) fueron más altos en CSM en comparación con SSM. HDL-C (40,7 ± 11,5 vs. 49,3 ± 9,8 mg/dl) fue menor en CSM en comparación con el SSM. El IMC (33,1 ± 4,7 vs. 30,8 ± 3,8 kg/m²) fue mayor en CSM en comparación con SSM. La PAS (128,6 ± 12,9 vs. 119,5 ± 11,3 mmHg) y la PAD (77,2 ± 10,5 vs. 72,9 ± 8,1 mmHg) fueron más altas en CSM en comparación con SSM, p < 0,05. Conclusión: Los resultados sugieren que la presencia de SM no es suficiente para provocar cambios en los índices de VFC en reposo durante las pruebas de ejercicio cardiopulmonar (PECP) y en la recuperación cuando se comparan los pacientes y los individuos saludables.

3.
Rio de janeiro; s.n; 2017. 124 p. ilus.
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-1015198

RESUMO

As técnicas clareadoras são consideradas seguras, simples e não invasivas. Assim, ganharam popularidade entre profissionais e pacientes. No entanto, o livre acesso do gel à estrutura dentária e o contato direto com a superfície do esmalte levantam dúvidas sobre seus reais impactos. Novas preocupações surgiram com os chamados produtos de bancada e a possibilidade de auto-aplicação, inclusive com consumo exagerado e/ou sem orientação e acompanhamento. Sendo assim, buscou-se avaliar, os efeitos de produtos clareadores caseiros sobre microestrutura, rugosidade, composição, nanodureza e módulo de elasticidade do esmalte dentário humano, em protocolos de uso normal ou excessivo. Amostras obtidas de 10 terceiros molares foram divididas em 4 grupos: grupo I ­ armazenamento em saliva artificial, grupo II ­ utilização de peróxido de carbamida (PC) 10%, grupo III ­ utilização de peróxido de hidrogênio (H2O2) 10%, grupo IV ­ utilização de tiras clareadoras (H2O2 10%). Cada dente forneceu quatro fragmentos de esmalte para cada um dos grupos. Foram realizadas aplicações diárias de acordo com a recomendação dos fabricantes, e foi adotada simulação de escovação duas vezes ao dia com escova elétrica. Todas as amostras foram armazenadas em saliva artificial e passaram por análises antes do início da terapia, após 4 e 8 semanas de intervenção. A escolha por técnicas não-destrutivas permitiu que cada amostra fosse seu próprio controle. Desse modo, a microscopia confocal por varredura a laser e microscopia de força atômica avaliaram alterações na microestrutura da superfície e foram coletados dados de rugosidade (Sa e Sq) para análise estatística. Os espécimes passaram por testes de nanoindentação para avaliação de nanodureza e módulo de elasticidade. Essas informações foram correlacionadas com as alterações de composição por microespectroscopia Raman. O clareamento com PC não apresentou alterações significativas nas amostras de esmalte, seguindo o padrão de comportamento daquelas escovadas e armazenadas em saliva artificial, tendo se mostrado segura. No entanto, os grupos que passaram por intervenção com H2O2 (III e IV) apresentaram modificações significativas em suas propriedades após 4 e 8 semanas de utilização. A alteração na superfície com aparência mais exposta foi associada a maior detecção de proteínas após as primeiras 4 semanas de utilização, especialmente para o grupo III. Após 8 semanas, a superfície apareceu mais suave, com perda do padrão prismático e queda no conteúdo orgânico, sugerindo uma perda de camadas superficiais desorganizadas. Do mesmo modo, o aumento dos valores de dureza e módulo de elasticidade para essas amostras pareceu derivar do efeito remineralizador da saliva e do papel positivo das proteínas mais expostas nas propriedades mecânicas permitindo maior deslizamento dos cristais e acomodação frente às cargas. Conclui-se que o uso de géis a base de H2O2 deve ser cauteloso, seguindo as recomendações profissionais e que são necessários testes in situ e in vivo para confirmar as tendências observadas.


The bleaching techniques are considered safe, simple and non-invasive and thus have gained popularity among professionals and patients. However, the free access of the gel to dental structures and the direct contact with the surface of the enamel, during the whole treatment raises doubts, about its possible impacts. Concerns were also raised about the emergence of so-called over-the-counter products and the possibility of self-application that could lead to excessive consumption and / or lack of guidance and monitoring. The aim of this study was to evaluate the effects of home bleaching products on the microstructure, roughness, composition, nanohardness and elastic modulus of human dental enamel in protocols of normal or excessive use. Samples were obtained from 10 third molars and divided into 4 groups: group I - storage in artificial saliva, group II - treatment with 10% carbamide peroxide, group III - treatment with 10% hydrogen peroxide, group IV - treatment with whitening strips (10% hydrogen peroxide). Each tooth provided four enamel fragments for treatment in each one of the groups. Daily applications were performed according to the manufacturers' recommendations, and a brushing simulation was used twice a day with an electric brush. All samples were stored in artificial saliva at the treatment intervals and were analyzed before the start of therapy, after 4 and 8 weeks of intervention. The choice by non-destructive techniques allowed each sample to be its own control. Qualitative analyzes of microstructure alteration were carried out using confocal laser scanning microscopy and atomic force microscopy. Roughness data (Sa and Sq) were also obtained for statistical analysis. Nanoindentation tests were used to determine changes in the nanohardness and elastic modulus. All of this information was correlated with composition changes by Raman micro-spectroscopy. Carbamide peroxide bleaching showed no significant changes in enamel samples, following the behavior pattern of those brushed and stored in artificial saliva, and therefore considered safe. However, the groups treated with hydrogen peroxide (III and IV) showed significant modifications in their properties after 4 and 8 weeks of treatment. The change in surface with more exposed appearance was associated with greater protein detection after the first month of treatment, especially for group III. After 8 weeks, the surface appeared smoother, with reduction of prismatic pattern and drop in organic content, suggesting a loss of disorganized mineral surface layers. Likewise, the increase in hardness and elastic modulus values for these samples seems to derive from the remineralizing effect of saliva and the positive role of the most exposed proteins in the mechanical properties, allowing greater slip of the crystals and accommodation with the loads. These changes may not reach clinically perceptible patterns but reinforce the importance of dentists' supervision and monitoring, since in-vivo the patient may be exposed to other challenges that may worsen the impacts. It is concluded that the use of hydrogen peroxide gels in bleaching therapies should be under professional supervision and that in situ and in vivo tests are required to confirm the observed trends.


Assuntos
Humanos , Clareamento Dental/efeitos adversos , Esmalte Dentário/efeitos dos fármacos , Clareadores Dentários/efeitos adversos , Peróxido de Hidrogênio/efeitos adversos , Análise Espectral Raman , Propriedades de Superfície , Microscopia Confocal
4.
Dement. neuropsychol ; 9(4): 385-393, Oct.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-770581

RESUMO

ABSTRACT Reduction of regional brain glucose metabolism (rBGM) measured by [18F]FDG-PET in the posterior cingulate cortex (PCC) has been associated with a higher conversion rate from mild cognitive impairment (MCI) to Alzheimer's disease (AD). Magnetic Resonance Spectroscopy (MRS) is a potential biomarker that has disclosed Naa/mI reductions within the PCC in both MCI and AD. Studies investigating the relationships between the two modalities are scarce. OBJECTIVE To evaluate differences and possible correlations between the findings of rBGM and NAA/mI in the PCC of individuals with AD, MCI and of cognitively normal volunteers. METHODS Patients diagnosed with AD (N=32) or MCI (N=27) and cognitively normal older adults (CG, N=28), were submitted to [18F]FDG-PET and MRS to analyze the PCC. The two methods were compared and possible correlations between the modalities were investigated. RESULTS The AD group exhibited rBGM reduction in the PCC when compared to the CG but not in the MCI group. MRS revealed lower NAA/mI values in the AD group compared to the CG but not in the MCI group. A positive correlation between rBGM and NAA/mI in the PCC was found. NAA/mI reduction in the PCC differentiated AD patients from control subjects with an area under the ROC curve of 0.70, while [18F]FDG-PET yielded a value of 0.93. CONCLUSION rBGM and Naa/mI in the PCC were positively correlated in patients with MCI and AD. [18F]FDG-PET had greater accuracy than MRS for discriminating AD patients from controls.


RESUMO Redução do metabolismo cerebral regional glicolítico (MRG) medido pela PET-18FDG no giro do cíngulo posterior (GCP) está relacionada a maior conversão para doença de Alzheimer (DA) em sujeitos com comprometimento cognitivo leve (CCL). Espectroscopia por ressonância magnética (MRS), um biomarcador promissor, demonstra redução de Naa/mI no GCP na DA. Raros estudos avaliam relações entre Naa/mI e MRG. OBJETIVO Avaliar diferenças e possíveis correlações entre MRG com PET-18FDG e Naa/mI por MRS no GCP de sujeitos com DA, CCL e voluntários normais. MÉTODOS Sujeitos com DA (N=32), CCL amnéstico (N=27) e voluntários idosos normais (GC, N=28), foram submetidos a PET-18FDG e análise de Naa/mI no GCP. A performance de ambos os métodos foi então comparada e verificou-se a existência de correlações entre os achados da PET e da MRS. RESULTADOS Observou-se hipometabolismo glicolítico nos pacientes com DA no GCP em relação ao GC, porém não no CCL. A MRS demonstrou valores menores de Naa/mI no CP do grupo DA em relação ao GC, porém também sem diferenças entre CCL e GC. A área sob a curva ROC demonstrou valor de 0,70 para MRS e 0,93 para o MRG no GCP para diferenciar DA do GC. Houve correlação positiva entre o MRG e o Naa/mI no GCP. CONCLUSÃO Os valores de metabolismo de glicose à PET e de Naa/mI à MRS no giro do cíngulo posterior apresentaram correlação positiva estatisticamente significante na presente amostra. Houve ainda superioridade da PET-18FDG para diferenciar DA do GC.


Assuntos
Humanos , Análise Espectral , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Doença de Alzheimer , Disfunção Cognitiva
5.
Acta sci., Biol. sci ; 36(4): 467-475, out.-dez. 2014. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-848490

RESUMO

Malnutrition is responsible for a number of alterations that occur in the organism, including alterations in the cardiovascular system. We hypothesize that long periods of malnutrition occurring after weaning may also be responsible for alterations in the cardiovascular system. Wistar rats were separated into the two following experimental groups: a labina® diet-fed control group (CG) and a malnourished group (MG), fed a multi- deficient diet. Results showed that the mg presented significantly lower body weight (p < 0.001) in rats of all ages, higher heart rate (HR) (p < 0.05) when rats were 3, 4 and 5 months old and lower HR in rats from 6 to 9 months of age, in relation to the CG. Spectral analysis showed a significant increase in the low frequencies (LF) components in the MG compared to the CG from the third month onwards (p < 0.05), showing evidence of sympathetic predominance greater cardiac autonomic balance in the MG versus that of CG indicated that, although aging influences autonomic behavior, it may also be altered by nutrition. Morphologically, an increase in the ventricle weight/body weight ratio was seen in the MG. These results show that the hearts of rats in the MG were not spared from malnutrition age-related detrimental cardiac effects associated with malnutrition.


A má nutrição é responsável por várias alterações que ocorrem no organismo, incluindo o sistema cardiovascular. Nossa hipótese é que longos períodos de desnutrição podem ser responsáveis por alterações no cardiovasculares. Ratos wistar foram separados em dois grupos experimentais: grupo controle (GC), alimentados com dieta labina® e um grupo malnutrido (GM), alimentados com dieta multideficiente. Resultados mostraram que GM apresentou menor peso corporal (p < 0,001) em todas as idades, maior frequência cardíaca (FC) (p < 0,05) nos ratos de três, quatro e cinco meses de idade e menor FC em ratos de seis a nove meses de idade, em relação ao GC. A análise espectral mostrou aumento nos componentes de baixas frequências (BF) no GM em relação ao GC a partir do terceiro mês (p < 0,05), mostrando evidências de predominância do simpático. Maior balanço autonômico cardíaco no GM em relação ao GC indicou que, embora o envelhecimento influencie o comportamento autonômico, pode também ser alterado pela nutrição. Morfologicamente, o aumento da proporção de peso de ventrículos/peso corporal do ventrículo foi visto no GM. Esses resultados mostram que os corações do GM não foram poupados pela má nutrição associada com a idade. Em detrimento dos efeitos cardíacos associados com a má nutrição.


Assuntos
Ratos , Envelhecimento , Pressão Arterial , Dieta , Eletrocardiografia , Frequência Cardíaca , Ventrículos do Coração , Análise Espectral
6.
Arq. bras. cardiol ; 103(2): 138-145, 08/2014. tab
Artigo em Inglês | LILACS | ID: lil-720819

RESUMO

Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents. .


Fundamento: O sistema nervoso autônomo tem papel central na regulação cardiovascular, ocorrendo uma ativação simpática durante a isquemia miocárdica. Objetivo: Avaliar a análise espectral da frequência cardíaca (AE) durante o implante de stent, comparando os tipos de stent. Métodos: Foram estudados 61 pacientes (idade média de 64 anos), 35 homens, com cardiopatia isquêmica e indicação de implante de stent. O implante foi feito sob monitoramento pelo Holter para o registro da AE (transformação de Fourier), com medidas dos componentes LF (baixa frequência), HF (alta frequência) e relação LF/HF, antes e durante o procedimento. Resultados: Implante de stent convencional feito em 34 pacientes; nos demais, farmacológico. A coronária abordada foi a direita em 21 pacientes, a descendente anterior em 28, a circunflexa em nove. Houve aumento do LF e do HF durante o implante em todos os pacientes, comparando-se com o período antes do implante (658 versus 185 ms2, p = 0,00, para LF; 322 versus 121 ms2, p = 0,00, para HF, respectivamente), sem alteração da LF/HF. LF durante o implante foi de 864 ms2 nos pacientes com stent convencional e de 398 com farmacológico (p = 0,00). Não houve associação entre a AE e a presença de diabetes, história familiar, apresentação clínica, uso de betabloqueador (BB), idade, vaso ou seu segmento. Conclusões: O implante de stent resultou em ativação simpática e concomitante ativação vagal. Não houve influência do quadro de diabetes, uso de BB e vaso sobre a AE. Houve menor ativação simpática durante o implante de stent farmacológico. .


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/métodos , Stents , Análise de Fourier , Estudos Longitudinais , Estudos Prospectivos , Valores de Referência , Estatísticas não Paramétricas , Sistema Nervoso Simpático/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
7.
Rev. bras. med. esporte ; 19(6): 457-461, nov.-dez. 2013. graf
Artigo em Português | LILACS | ID: lil-697998

RESUMO

INTRODUÇÃO: A reprodutibilidade da atividade eletromiográfica de superfície (EMG) é mais estudada em protocolos que envolvem contrações isométricas. Alguns fatores relacionados às contrações dinâmicas podem contribuir para a instabilidade do sinal mioelétrico e dificultar a reprodutibilidade da medida da EMG. OBJETIVO: Determinar a reprodutibilidade teste-reteste e quantificar o erro técnico da medida da frequência mediana (FM) e da amplitude (root mean square, RMS) da EMG, em contrações dinâmicas e estáticas. MÉTODOS: Dez sujeitos foram testados em dois dias, sendo a atividade EMG registrada na maior porção do bíceps braquial. No primeiro dia foi feito o teste de uma repetição máxima (1RM) e de contração voluntária máxima (CVM). No segundo dia foram realizadas duas séries de 10 contrações dos flexores do cotovelo com 75% de 1RM, entremeadas por 1 h em repouso. Antes de cada série foi realizada uma CVM. RESULTADOS: Para a FM e RMS foi observado alto coeficiente de correlação intraclasse para o sinal do bíceps braquial (CCI = 0,90-0,98 para a FM; CCI = 0,89-0,94 para o RMS) e de baixo para moderado coeficiente de variação (CV = 2,5-6,2% para a FM; CV = 14,6-16,3% para o RMS) em ambos os testes. Não foi observada diferença significativa entre teste e reteste (p > 0,05). CONCLUSÃO: A FM e o RMS apresentam alta confiabilidade e baixo a moderado erro em contrações estáticas e dinâmicas, possibilitando o uso da EMG para investigação da fadiga e de desordens neuromusculares.


INTRODUCTION: Reproducibility of electromyographic activity (EMG) is the most studied in protocols involving isometric contractions. Some factors related to dynamic contractions may contribute to the instability of the myoelectric signal and affect the reproducibility of the measurement of EMG. OBJECTIVE: To determine the test-retest reproducibility and quantify the technical error of the measurement of the median frequency (MF) and amplitude (root mean square, RMS) of the surface EMG in static and dynamic contractions. METHODS: Ten subjects were tested in two days with the EMG activity recorded for the greatest portion of the biceps brachii tendon. In the first day the subjects did one test of maximum repetition (1MR) and maximal voluntary contraction (MVC). On the second day the subjects performed two sets of 10 dynamic contractions of the elbow flexors at 75% of 1MR interspersed by 1 h at rest. Before each set one MVC was performed. RESULTS: For both MF and RMS, was observed high intraclass reliability for biceps brachii (ICC = 0.90-0.98 for MF; ICC = 0.89-0.94 for RMS) and low to moderate coefficient of variation (CV = 2.5-6.2% for MF; CV =14.6-16.3% for RMS) in both tests. No significant difference between test and retest was found (p>0.05). CONCLUSION: The MF and RMS have high reliability and low to moderate error in static and dynamic contractions, enabling the use of EMG for the investigation of fatigue and neuromuscular disorders.


INTRODUCCIÓN: La reproducibilidad de la actividad electromiográfica de superficie (EMG) es más estudiada en protocolos que involucran contracciones isométricas. Algunos factores relacionados con las contracciones dinámicas pueden contribuir para la inestabilidad de la señal mioeléctrica y dificultar la reproducibilidad de la medida de la EMG. OBJETIVO: Determinar la reproducibilidad prueba-nueva prueba y cuantificar el error técnico cuanto a la medida de la frecuencia mediana (FM) y de la amplitud (root mean square, RMS) de la EMG de superficie, en contracciones dinámicas y estáticas. MÉTODOS: diez individuos fueron examinados en dos días, siendo la actividad EMG registrada en el área más grande del bíceps braquial. En el primer día, se hizo la prueba de una repetición máxima (1RM) y de contracción voluntaria máxima (CVM). En el segundo día, se realizaron dos series de 10 contracciones de los flexores del codo, con 75% de 1RM, alternadas por 1 hora en reposo. Antes de cada serie, se hizo una CVM. RESULTADOS: Para la FM y el RMS se observó un alto coeficiente de correlación para la señal del bíceps braquial (CCI = 0,90-0,98 para la FM; CCI = 0,89-0,94 para el RMS) y un coeficiente de variación de bajo para moderado (CV = 2,5-6,2% para la FM; CV = 14,6-16,3% para el RMS) en ambas pruebas. No se observó una diferencia significativa entre prueba y nueva prueba (p > 0,05). CONCLUSIÓN: La FM y el RMS presentan alta confiabilidad, y error de bajo a moderado en contracciones estáticas y dinámicas, posibilitando el uso de la EMG para investigación de la fatiga y de desórdenes neuromusculares.

8.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-857054

RESUMO

Introdução: O diagnóstico óptico através da espectroscopiaRaman é amplamente utilizado na indústria para estudo decomposição de materiais e recentemente foi introduzido emanálises de tecidos biológicos. É possível a caracterizaçãode lesões através de alterações bioquímicas identificadasprecocemente às alterações morfológicas. Objetivo: caracterizare diferenciar tecidos normais de tumorais da tireoide pelatécnica de espectroscopia Raman confocal. Método: Um totalde 21 espectros de tecido de tireoide, sendo 8 normais e 13tumorais (carcinoma papilífero), foram obtidos pela técnica deespectroscopia Raman confocal e processados pelos softwaresMatlab 6.1, Origin 8.6 e OPUS®. A análise estatística para aseparação das amostras baseados nas características bioquímicasde cada grupo foi realizada pelo programa Minitab®. Resultados:um importante aumento de intensidade de alguns modosvibracionais foi verificado nos espectros de câncer em relação aonormal. A análise multivariada possibilitou diferenciação de 100%para tecidos normais e de 84,6% para tumorais, o que equivalea uma proporção discriminante de 90,5%. Conclusão: A técnicade espectroscopia Raman se mostrou eficiente na detecção dealterações bioquímicas das lesões de tireoide e na diferenciaçãoentre os tecidos.


Assuntos
Análise Espectral Raman , Diagnóstico , Glândula Tireoide
9.
Braz. j. otorhinolaryngol. (Impr.) ; 78(4): 108-114, jul.-ago. 2012. tab
Artigo em Português | LILACS | ID: lil-646780

RESUMO

O grau de nocividade do ruído pode ser quantificado e qualificado com base em algumas características do som como sua intensidade, o tipo de espectro, duração e a distribuição da exposição ao ruído durante a jornada de trabalho. OBJETIVO: Avaliar o espectro de ruído e a configuração audiométrica em trabalhadores. MATERIAIS E MÉTODOS: Estudo de coorte contemporânea com corte transversal, realizado no Distrito Federal. Realizou-se avaliação ambiental (análise espectral) do ruído em empresas de diferentes ramos de atividade econômica e avaliação audiológica em 347 trabalhadores. RESULTADOS: A análise espectral revelou picos em diferentes frequências em cada ramo de atividade (8 kHz-metalúrgico, 4 kHz-marmoraria e 2 kHz-madeireira). Verificou-se que as frequências de 14 kHz e 16 kHz apresentaram diferenças significativas entre os ramos de atividade, com maior prevalência no metalúrgico. CONCLUSÃO: A utilização de medidor de nível de pressão sonora, acoplado a analisador de frequência e a avaliação audiométrica de altas frequências possibilitam a detecção precoce de danos auditivos que, por sua vez, viabiliza melhor direcionamento das ações preventivas.


Noise level can be quantified and qualified based on sound characteristics such as intensity, type of spectrum, duration and distribution of the noise exposure during one's working hours. OBJECTIVE: To assess noise spectrum and the audiometric configuration of workers. MATERIALS AND METHODS: Contemporary cross-sectional cohort carried out in the Federal District - Brazil. We did an environmental analysis (spectral analysis) of the noise in companies from different industries, with audiological assessment of 347 workers. RESULTS: The spectral analysis revealed peaks at different frequencies for each industry investigated (8 kHz-metallurgical, 4 kHz-stone Works and 2 kHz-wood works). We noticed that the frequencies of 14 kHz and 16 kHz had significant differences between the various industries, with a greater prevalence of the metallurgical. CONCLUSION: The use of noise pressure measuring device, coupled to a frequency analyzer and high frequency audiometric assessment yielded an early detection of hearing damage, helping better organize preventive measures.


Assuntos
Humanos , Masculino , Perda Auditiva Provocada por Ruído/diagnóstico , Ruído Ocupacional/efeitos adversos , Ocupações/classificação , Audiometria , Estudos de Coortes , Estudos Transversais , Ruído Ocupacional/estatística & dados numéricos , Ocupações/estatística & dados numéricos
10.
Arq. bras. cardiol ; 98(4): 353-361, abr. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-639416

RESUMO

FUNDAMENTO: O envolvimento cardíaco é comum em pacientes com Distrofia Miotônica (DM). A Variabilidade da Frequência Cardíaca (VFC) é uma técnica simples e confiável que pode ser útil para estudar a influência do sistema nervoso autonômico sobre o coração. OBJETIVO: Estudar a variabilidade da frequência cardíaca em pacientes com DM tipo 1. MÉTODOS: Estudamos a VFC durante registros de 5 minutos em pacientes com DM em um grupo controle saudável. Analisamos os domínios da frequência (BF e AF) em unidades normalizadas (un) e balanço simpático-vagal, na posição sentada e em decúbito dorsal. RESULTADOS: Dezessete pacientes (10 homens e 7 mulheres) e dezessete indivíduos pareados saudáveis (10 homens e 7 mulheres) foram estudados. As modulações simpática e parassimpática do coração elevadas em pacientes do sexo masculino com DM da posição em decúbito dorsal para a posição sentada em 19% da AFun e a razão BF/AF aumentaram 42,3%. Na posição sentada, os pacientes do sexo masculino com DM apresentaram balanços simpático-vagal significativamente mais elevados em 50,9% em comparação com indivíduos controles saudáveis. A VFC foi influenciada tanto pelo sexo quanto pela enfermidade apresentada. O sexo influenciou a AFun na posição em decúbito dorsal, enquanto a razão BF/AF e AFun foi afetada em ambas as posições. Análises post hoc mostraram que o sexo afeta significativamente pacientes com DM e indivíduos saudáveis de diferentes maneiras (p < 0,01). O domínio de baixa frequência na posição sentada (AFun) foi significativamente influenciado pela enfermidade. CONCLUSÃO: Os resultados deste estudo sugerem que o estímulo simpático em pacientes de meia-idade do sexo masculino com DM que não está gravemente comprometido e apresenta duração moderada da doença parece ser maior do que em indivíduos saudáveis pareados.


BACKGROUND: Cardiac involvement is common in myotonic dystrophy (MD) patients. Heart rate variability (HRV) is a simple and reliable technique that can be useful for studying the influence of the autonomic nervous system on the heart. OBJECTIVE: Study heart rate variability in patients with type 1 MD. METHODS: We studied HRV during 5-minute recordings in MD patients and in a healthy control group. We analyzed frequency domains (LF and HF) in normalized units (nu) and sympathovagal balance, in the sitting and supine position. RESULTS: Seventeen patients (10 men and 7 women) and seventeen matched healthy individuals (10 men and 7 women) were studied. Sympathetic and parasympathetic modulations of the heart increased in male MD patients from supine to sitting position in 19% of LFnu and the LF/HF ratio rose by 42.3%. In the sitting position, male MD patients exhibited significantly higher sympathovagal balances in 50.9% compared to healthy control individuals. HRV was influenced by both gender and disease. Gender influenced LFnu in the supine position while the LF/HF ratio and HFnu were affected in both positions. Post hoc analyses showed that gender significantly impacts MD patients and healthy individuals in different ways (p < 0.01). The low frequency domain in the sitting position (LFnu) was significantly influenced by the disease. CONCLUSION: The results of this study suggest that the sympathetic drive in middle-aged male MD patients who are not severely impaired and present moderate disease duration seems to be greater than in healthy matched individuals.


Assuntos
Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Distrofia Miotônica/fisiopatologia , Análise de Variância , Sistema Nervoso Autônomo/fisiologia , Índice de Massa Corporal , Estudos de Casos e Controles , Fatores Sexuais , Fatores de Tempo
11.
Arq. neuropsiquiatr ; 69(6): 871-874, Dec. 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-612623

RESUMO

There is evidence in electroencephalography that alpha, theta and delta band oscillations reflect cognitive and memory performances and that quantitative techniques can improve the electroencephalogram (EEG) sensitivity. This paper presents the results of comparative analysis of qEEG variables as reliable markers for Alzheimer's disease (AD). We compared the sensitivity and specificity between spectral analysis (spectA) and coherence (Coh) within the same group of AD patients. SpectA and Coh were calculated from EEGs of 40 patients with mild to moderate AD and 40 healthy elderly controls. The peak of spectA was smaller in the AD group than in controls. AD group showed predominance of slow spectA in theta and delta bands and a significant reduction of inter-hemispheric Coh for occipital alpha 2 and beta 1 and for frontal delta sub-band. ROC curve supported that alpha band spectA was more sensitive than coherence to differentiate controls from AD.


Há evidências de que as oscilações das bandas teta, alfa e delta no eletroencefalograma podem refletir diferenças na cognição e memória; a sensibilidade deste método diagnóstico pode ser melhorada por técnicas de quantificação. Comparamos a sensibilidade e especificidade entre a análise espectral (spectA) e coerência (Coh) dentro do mesmo grupo de pacientes com doença de Alzheimer (DA) e contra um grupo controle. SpectA e Coh foram calculadas a partir de EEGs de 40 pacientes com DA leve a moderada e 40 idosos saudáveis. O pico do espectro foi menor no grupo DA que nos controles. O grupo DA também apresentou um espectro mais lento nas bandas teta e delta e menor coerência inter-hemisférica para as sub-bandas alfa 2 e beta 1 posterior e delta frontal. A curva ROC suporta que a análise espectral da banda alfa foi mais sensível que a coerência para diferenciar controles de DA.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Doença de Alzheimer/diagnóstico , Eletroencefalografia/métodos , Ritmo alfa/fisiologia , Doença de Alzheimer/fisiopatologia , Ritmo beta/fisiologia , Estudos de Casos e Controles , Curva ROC , Sensibilidade e Especificidade , Índice de Gravidade de Doença
12.
Rev. Soc. Bras. Med. Trop ; 44(3): 297-299, May-June 2011. graf
Artigo em Inglês | LILACS | ID: lil-593347

RESUMO

INTRODUCTION: Sylvatic yellow fever (SYF) is enzootic in Brazil, causing periodic outbreaks in humans living near forest borders or in rural areas. In this study, the cycling patterns of this arbovirosis were analyzed. METHODS: Spectral Fourier analysis was used to capture the periodicity patterns of SYF in time series. RESULTS: SYF outbreaks have not increased in frequency, only in the number of cases. There are two dominant cycles in SYF outbreaks, a seven year cycle for the central-western region and a 14 year cycle for the northern region. Most of the variance was concentrated in the central-western region and dominated the entire endemic region. CONCLUSIONS: The seven year cycle is predominant in the endemic region of the disease due the greater contribution of variance in the central-western region; however, it was possible identify a 14 cycle that governs SYF outbreaks in the northern region. No periodicities were identified for the remaining geographical regions.


INTRODUÇÃO: A febre amarela silvestre (FAS) é enzoótica no Brasil, causando surtos periódicos em humanos que vivem próximos às áreas florestais ou em áreas rurais. Neste estudo, foram analisados os padrões de periodicidade desta arbovirose. MÉTODOS: Utilizamos a análise espectral de Fourier para capturar os padrões de periodicidades da FAS em séries temporais. RESULTADOS: Os surtos de FAS aparentemente não aumentaram em frequência, mas em número de casos. Há dois ciclos dominantes na FAS, um de sete anos predominando na região centro-oeste, e um de 14 anos predominando na região norte. A maior parte da variância concentrou-se na região centro-oeste e dominava toda região endêmica. CONCLUSÕES: O ciclo de sete anos é predominante para a região endêmica da doença devido a maior contribuição da variância do centro-oeste. No entanto, foi possível identificar um ciclo de 14 que rege a FAS na região norte. Não foram detectadas periodicidades nas demais regiões geográficas.


Assuntos
Humanos , Surtos de Doenças , Periodicidade , Febre Amarela/epidemiologia , Brasil/epidemiologia
13.
Rev. méd. Minas Gerais ; 21(2 supl.3): 49-57, abri.-jun.2011. tab
Artigo em Português | LILACS | ID: lil-786239

RESUMO

O índice bispectral (BIS) é um parâmetro multifatorial que permite a monitorização da componente hipnótico da anestesia. O BIS provê medidas quantificáveis do efeito de anestésicos no cérebro que correlacionam com a profundidade da anestesia. A monito-rização da profundidade anestésica na indução e manutenção da anestesia geral previne consciência e despertar intraoperatório, permite titular a quantidade de anestésicos adequada para promover a rápida recuperação da anestesia e evitar efeitos adversos da superdosagem dos fármacos. Desde sua introdução, a monitorização com BIS vem se tornando comum na prática anestésica. Esta revisão tem o objetivo de elucidar o papel do BIS na monitorização da hipnose na anestesia geral. Foi realizada revisão sobre o conceito de anestesia geral e monitorização da profundidade anestésica com o uso do BIS, bem como atualizações dos benefícios de seu emprego para a qualidade da anestesia, interpretação dos artefatos e drogas que podem interferir na sua utilização...


The bispectral index (BIS) is a multifactorial parameter that allows monitoring of the hypnotic component of anesthesia. The BIS provides quantitiable measures of the effect of anesthetics in the brain that correia te with the depth of anesthesia. Monitoring anesthetic depth during induction and maintenance of general anesthesia prevents intraoperative awakening and conscience and allows to holder the amount of anesthetic agents appropriate to promote a speedy recovery of anesthesia and avoid adverse effects of an overdose of drugs. Since its introduction, the BIS monitoring is becoming acommonplace in anesthetic practice. This review has the objective of elucidating the role of BIS monitor- ing in hypnosis of general anesthesia. A Literature review was conducted on the concepts of general anesthesia and monitoring of anesthetic depth using the BIS Moreover, recent articles on studies of BIS and its benetits in the quality of general anesthesia as well as the presence of artifacts and drugs that may interfere in its utilization...


Assuntos
Humanos , Anestésicos/administração & dosagem , Consciência no Peroperatório , Hipnose Anestésica/instrumentação , Hipnóticos e Sedativos/administração & dosagem , Monitores de Consciência , Anestesia Geral/instrumentação , Eletroencefalografia/instrumentação , Processamento de Imagem Assistida por Computador
14.
São José dos Campos; s.n; 2011. 80 p. ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-642727

RESUMO

A queilite actínica (QA) é uma lesão considerada potencialmente cancerizável, localizada principalmente em lábio inferior e causada pela exposição crônica à radiação UV. A Espectroscopia FT-IR fornece informações moleculares através de fenômenos ópticos observado pela vibração de suas moléculas. Tem sido empregada em estudos biológicos para a caracterização de alterações neoplásicas. No entanto, são escassos os estudos que envolvam processos potencialmente cancerizáveis. Objetivou-se avaliar Q As através da espectroscopia micro FT-IR com relação aos seus aspectos moleculares para região de finger print (900-1800 cm-1) e altos números de onda (2800-3600 cm-1), e ainda verificar a análise dos componentes principais (PCA) e regressão logística binária (RLB) como modelo de diagnóstico. Foram avaliadas 14 amostras de QA e14 amostras de mucosas normal (MN), obtendo-se 5 espectros por amostra, totalizando 140 espectros avaliados (70 de cada grupo). Os resultados demonstrados pela análise dos componentes principais revelaram pelo gráfico de scree plot que os dez primeiros PCs deveriam ser utilizados na análise. As maiores variações observadas pelo gráfico de loading plot relacionaram-se aos modos vibracionais do colágeno, ácidos nucléicos, lipídios e água confinada. O modelode regressão logística binária mostrou 80,6% de pares concordantes para região de finger print e 81,7% de pares concordantes para a região de altos números de onda. Concluiu-se que a espectroscopia micro FT-IR provê características moleculares importantes das19 amostras de QA, evidenciadas tanto na região de finger print como na de altos números de onda.


Actinic cheilitis (AC) is a potentially precancerous lesion, located primarily in lower lip caused by chronic exposure to UV radiation.The FT-IR spectroscopy provides molecular information through optical properties observed by the vibration of its molecules. This technique has been used in biological studies for characterization of neoplastic tissues. However, there are few studies involving potentially cancerous processes. This study aimed to evaluate molecular changes on AC through micro FT-IR spectroscopy infinger print (900-1800 cm-1) and high wave numbers (2800-3600 cm-1) region, and also to verify the principal components analysis (PCA)and binary logistic regression (BLR) as a model of diagnosis. We evaluated 14 samples of AC and 14 samples of normal mucosa (NM),resulting in 5 spectra per sample, totalling 140 spectra analyzed (70from each group). The results demonstrated by PCA revealed byscree plot graph showed that the first ten principal components(PCs) should be used in the analysis. The largest variations observedby loading graph plot related to the vibrational modes of collagen,nucleic acids, lipids and confined water. The BLR model showed80.6% of concordant pairs for the finger print region and 81.7% of concordant pairs of high wave numbers region. It was concluded that the micro FT-IR spectroscopy provides important molecular features of AC samples, evidenced both in the finger print and in thehigh wave numbers region.


Assuntos
Humanos , Queilite , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral
15.
Pró-fono ; 22(4): 515-520, out.-dez. 2010. ilus, graf
Artigo em Português | LILACS | ID: lil-572522

RESUMO

TEMA: o controle do tamanho da abertura velofaríngea é uma variável importante na caracterização do perfil acústico da fala hipernasal. OBJETIVO: investigar os aspectos espectrais das frequências de F1, F2, F3, formante nasal(FN) e anti-formante, em Hertz, para as vogais [a] e [ã] na presença de aberturas feitas no bulbo de réplicas da prótese de palato de uma paciente com insuficiência velofaríngea. MÉTODO: gravações de produções de quatro palavras ("pato/mato" e "panto/manto") inseridas em frase veículo foram obtidas em cinco condições de funcionamento velofaríngeo: prótese sem aberturas (condição controle: CC), prótese com abertura de 10mm² no bulbo (condição experimental - CE10), com abertura de 20mm² (condição experimental - CE20), com abertura de 30mm² (condição experimental - CE30), e sem prótese (condição experimental aberta - CEA). Cinco fonoaudiólogos julgaram a nasalidade de fala ao vivo, durante a leitura de um texto oral. As gravações foram usadas para análise espectral. RESULTADOS: valores de F1 foram significativamente mais altos para [a] que para [ã] em todas as condições. Valores de F2 para [a] em CE20 e CE30 foram significantemente mais baixos que nas outras condições, aproximando-se dos valores para [ã]. Valores de F3 não foram significativamente diferentes nas diferentes condições. Houve relação entre os achados de FN e anti-formantes e a percepção de nasalidade para as condições CE10 e CE20. CONCLUSÃO: foram observadas mudanças significativas nos valores espectrais estudados de acordo com alterações no tamanho da abertura velofaríngea.


BACKGROUND: the size control of velopharyngeal opening is an important variable for the acoustic profile characterization of hypernasal speech. AIM: to investigate frequency spectral aspects of F1, F2, F3, nasal formant (FN) and anti-formant, in Hertz, for vowels [a] and at different velopharyngeal openings produced in the bulb of a palatal prosthesis replica used by a patient with velopharyngeal insufficiency. METHOD: speech recordings were obtained for four words ("pato/mato" and "panto/manto") produced within a carrier phrase in 5 conditions of velopharyngeal functioning: prosthesis with no openings (control condition: CC); prosthesis with bulb opening of 10mm² (experimental condition with 10mm² opening: EC10), prosthesis with a 20mm² opening (EC20), prosthesis with a 30mm² openning (EC30), and without the prosthesis (ECO). Five speech-language pathologists made a live rating of speech nasality during the reading of an oral passage. The recordings were used for spectral analysis. RESULTS: F1 values were significantly higher for [a] when compared to in all conditions. F2 values for [a] in EC20 and EC30 were significantly lower than values in the other conditions, being closer to the values presented for . F3 values were not significantly different between the testing conditions. There was a relationship between FN and anti-formants, and the auditory perception of nasality for conditions EC10 and EC20. CONCLUSION: significant changes were observed in the studied spectral values according to changes in the velopharyngeal opening size.


Assuntos
Adolescente , Feminino , Humanos , Obturadores Palatinos , Acústica da Fala , Qualidade da Voz , Insuficiência Velofaríngea , Análise de Variância , Análise Espectral , Espectrografia do Som/métodos , Distúrbios da Fala , Medida da Produção da Fala/métodos
16.
Acta cir. bras ; 25(5): 434-439, Sept.-Oct. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-558730

RESUMO

PURPOSE: To qualify the FT-Raman spectral data of primary and metastatic cutaneous melanoma in order to obtain a differential diagnosis. METHODS: Ten normal human skin samples without any clinical or histopathological alterations, ten cutaneous melanoma fragments, and nine lymph node metastasis samples were used; 105, 140 and 126 spectra were obtained respectively. Each sample was divided into 2 or 3 fragments of approximately 2 mm³ and positioned in the Raman spectrometer sample holder in order to obtain the spectra; a monochrome laser light Nd:YAG at 1064 nm was used to excite the inelastic effect. RESULTS: To differentiate the three histopathological groups according to their characteristics extracted from the spectra, data discriminative analysis was undertaken. Phenylalanine, DNA, and Amide-I spectral variables stood out in the differentiation of the three groups. The percentages of correctly classified groups based on Phenylalanine, DNA, and Amide-I spectral features was 93.1 percent. CONCLUSION: FT-Raman spectroscopy is capable of differentiating melanoma from its metastasis, as well as from normal skin.


OBJETIVO: Qualificar os dados espectrais FT-Raman do melanoma cutâneo primário e metastático e assim realizar o diagnóstico diferencial. MÉTODOS: Foram utilizadas amostras de 10 fragmentos de pele sem alterações clínicas ou histopatológicas, 10 de melanomas cutâneos e 9 de metástases linfonodais; 105, 140 and 126 espectros foram obtidos respectivamente. Cada amostra foi dividida em 2 ou 3 frações de 2 mm³ e posicionada no porta amostras do espectrômetro Raman para obtenção dos espectros, por meio da excitação do espalhamento inelástico pelo laser de Nd:YAG em 1064 nm incididos na amostra. RESULTADOS: Para diferenciar os três grupos formados de acordo com as características fornecidas pelos espectros, realizamos a análise discriminante dos dados. As variáveis espectrais Fenilalanina, DNA e Amida-I se destacaram na capacidade de diferenciação dos três grupos histológicos. A porcentagem de classificação correta utilizando estes critérios foi de 93,1 por cento; o que mostra a eficiência da análise realizada. CONCLUSÃO: A espectroscopia FT-Raman é capaz de diferenciar o melanoma de sua metástase, assim como da pele normal.


Assuntos
Humanos , Melanoma/diagnóstico , Neoplasias Cutâneas/diagnóstico , Análise Espectral Raman/normas , Amidas/análise , Diagnóstico Diferencial , DNA , Melanoma/química , Melanoma/secundário , Fenilalanina/análise , Neoplasias Cutâneas/química , Neoplasias Cutâneas/patologia , Pele/química , Análise Espectral Raman/métodos
17.
Acta cir. bras ; 25(4): 351-356, July-Aug. 2010. graf, tab, ilus
Artigo em Inglês | LILACS | ID: lil-553243

RESUMO

Cutaneous melanoma is the most aggressive type of skin cancer and Ft-Raman spectroscopy has been studied as a potential method that could be a real alternative for early diagnosis of neoplasms. PURPOSE: To qualify the spectral FT-Raman data, in order to differentiate cutaneous melanoma and pigmented nevus. METHODS: For this study, 10 samples of cutaneous melanoma, 9 samples of pigmented nevi, and 10 samples of normal skin were obtained by incisional biopsies performed during plastic surgeries ex vivo, immediately after removing the surgical sample. RESULTS: The FT-Raman spectra of each group presented a high correlation between the elements of the same group, thus favoring the elaboration of spectral averages. When analyzing the spectral standard of each group, the normal skin standard did not show a significant variation between the spectra; the standard of the pigmented nevi group showed significant variation, and the cutaneous melanoma group also showed variation. Through univariate analysis, specific bands were detected for each vibrational mode identified. The discriminatory analysis of the data showed a 75.3 percent efficiency of the differentiation between the three groups studied. CONCLUSION: The vibrational modes Polysaccharides, Tyrosine and Amide-I differentiated the melanoma from the pigmented nevus.


O melanoma cutâneo é o câncer de pele mais agressivo, e a espectroscopia FT-Raman tem sido estudada como um método em potencial que pode ser uma verdadeira alternativa no diagnóstico precoce de neoplasias. OBJETIVO: Qualificar os dados espectrais FT-Raman de modo a diferenciar melanoma cutâneo de nevo pigmentado. MÉTODOS: Foram utilizadas 10 amostras de melanoma cutâneo, obtidas por meio de biopsias incisionais realizadas "ex-vivo"; nove amostras de nevo pigmentado e 10 amostras de pele normal foram coletadas durante cirurgias plásticas. RESULTADOS: Os espectros FT-Raman de cada grupo diagnóstico apresentaram alta correlação entre os elementos do mesmo grupo, o que favoreceu a realização das médias espectrais. Analisando o padrão espectral de cada grupo, o de pele normal não mostrou grande variação entre os espectros; o de nevo pigmentado apresentou variação notável e, o grupo melanoma primário também indicou variação. Por meio de análise univariada foram identificadas bandas específicas para cada modo vibracional identificado. A análise discriminante aos dados mostrou 75,3 por cento de eficiência na diferenciação entre os três grupos estudados. CONCLUSÃO: Os modos vibracionais Polissacarídeos (Banda I), Tirosina (Banda 6) e Amida I (Banda 10) diferenciaram o melanoma do nevo pigmentado.


Assuntos
Humanos , Melanoma/patologia , Nevo Pigmentado/patologia , Neoplasias Cutâneas/patologia , Análise de Variância , Biópsia , Diagnóstico Diferencial , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Espectral Raman/métodos
18.
Rev. bras. cineantropom. desempenho hum ; 11(1): 30-36, 02 mar. 2009. ilus, graf, tab
Artigo em Português | LILACS-Express | LILACS | ID: lil-515567

RESUMO

O objetivo deste estudo foi avaliar os parâmetros de freqüência e amplitude da eletromiografia de superfície durante a fadiga dos músculos paraespinhais em indivíduos saudáveis na posição sentada. Participaram do estudo 11 indivíduos do gênero masculino, saudáveis e livres de sintomas de dor lombar. Um eletromiógrafo de superfície foi utilizado para obtenção dos parâmetros eletromiográficos. Foram posicionados quatro eletrodos lateralmente aos processos espinhosos da primeira equinta vértebras lombares. Os sinais foram registrados mediante a extensão de tronco na posição sentada contra a resistência de uma célula de carga. Foram utilizadas as cargas de 50% e 75% da contração isométrica voluntária máxima, por 25 segundos, para induzir os sujeitos à fadiga muscular. Os sinais eletromiográficos processados pelo algoritmo da Transformada Rápida de Fourier e pela raiz quadrática média foramsubmetidos à regressão linear para se determinar o índice de fadiga. A freqüência mediana do espectro de potência apresentou valores negativos, assim como a amplitude eletromiográfica valores positivos, o que representa a fadiga muscular. Quando se comparou a altura e o lado, bem como as duas cargas, não foram observadas diferenças estatisticamente significante (P > 0,05). Na posição sentada, é possível obter uma melhor fixação da pelve, além de reproduzir uma posição usual das atividades ocupacionais. O protocolo utilizado não causou dor nos sujeitos. Apesar de todos os indivíduos apresentarem fadiga, não houve diferença quanto às regiões da coluna lombar. Sugere-se a utilização da freqüência mediana e da raiz quadrática média concomitante nos estudos de fadiga.


The aim of this study was to evaluate the frequency and amplitude of surface electromyography during erector spinae fatigue in healthy subjects in the sitting position. Eleven healthy males without low back pain participated in the study. The electromyographic parameters were collected with a surface electromyograph. Four electrodes were positioned lateral to the first and fifth lumbar vertebrae. The electromyographic signals were recorded during isometric trunk extension against a load cell in the sitting position. Loads of 50% and 75% of maximal voluntary isometric contraction were applied for 25 seconds to induce muscle fatigue. The signals processed using a Fast Fourier Transform algorithm and root mean square were submitted to linear regression to determine the fatigue index. The median frequency of the power spectrum presented negative values and the root mean square presented positive values, indicating muscle fatigue. No significant differences were observed when comparing level and side, or between loads (P > 0.05). The sitting position provides a better pelvis fixation and reproduces the usual position of occupational activities. The protocol used did not cause pain. Although all subjects presented erector spinae fatigue, no differences were observed between lumbar regions. The concomitant use of median frequency and root mean square in fatigue studies is suggested.

19.
Rev. Assoc. Med. Bras. (1992) ; 55(1): 35-39, 2009. graf
Artigo em Português | LILACS | ID: lil-511063

RESUMO

OBJETIVOS: Determinar os níveis dos metabólitos (mio-inositol [MI], colina [Cho], glutamina [Glx], creatina [Cr] e N-acetilaspartato [NAA]) por meio da espectroscopia por ressonância magnética em portadores de hepatopatia crônica, antes e após o transplante hepático, correlacionando com a avaliação clínica. MÉTODOS: Foram estudados prospectivamente 25 pacientes portadores de hepatopatia crônica do Serviço de Transplante Hepático da Universidade Federal do Paraná por meio de avaliação clínica e espectroscópica. Trinta voluntários sadios formaram o grupo controle, sendo submetidos às mesmas avaliações. Dezesseis dos 25 pacientes também foram avaliados após o transplante. RESULTADOS: Antes do transplante hepático reduções significativas nos índices de MI/Cr e Cho/Cr e aumento significativo no índice de Glx/Cr foram observadas nos pacientes portadores de encefalopatia hepática comparados ao grupo controle. Os critérios quantitativos de Ross para diagnóstico espectroscópico da encefalopatia hepática (MI/Cr e Cho/Cr < média + 2 desvios padrão do grupo controle) demonstraram uma sensibilidade de 61,54 por cento, especificidade de 91,67 por cento e precisão de 76 por cento, sendo que a Cho/Cr foi o melhor parâmetro isolado. A espectroscopia após o transplante mostrou mudanças nos índices metabólicos comparados com o status pré-transplante. CONCLUSÃO: A espectroscopia permite um diagnóstico preciso da encefalopatia hepática. A melhora dos níveis metabólicos após o transplante hepático sugere um importante papel do MI e da Cho no desenvolvimento da encefalopatia hepática.


OBJECTIVES: To determine the metabolite levels (myo-inositol [MI], choline [Cho], glutamate [Glx], creatine [Cr] and N-acetylaspartate [NAA]) visible on magnetic resonance spectroscopy in patients with chronic hepatic failure, before and after liver transplantation and to correlate these data with results of neuropsychiatric tests and clinical findings. METHODS: Twenty five patients with chronic hepatic failure from the Liver Transplantation Unit of the Federal University of Parana were prospectively studied. Patients were submitted to clinical evaluation and magnetic resonance spectroscopy. Thirty healthy volunteers also submitted to the same evaluations. Sixteen of the 25 patients were evaluated after liver transplantation. RESULTS: Before liver transplantation, significant reductions in MI/Cr and Cho/Cr and a significant increase in Glx/Cr were observed in patients with hepatic encephalopathy compared with healthy subjects. The Ross's criteria for spectroscopic diagnosis of the hepatic encephalopathy (MI/Cr and Cho/Cr lower than 2 SD of controls) demonstrated a sensitivity of 61.54 percent, specificity of 91.67 percent and accuracy of 76 percent, further Cho/Cr was the best parameter. Spectroscopy after liver transplantation showed changes in the metabolite ratios compared with the pretransplantation status. CONCLUSION: Magnetic resonance spectroscopy permits an accurate diagnosis of hepatic encephalopathy. Improvement of metabolic ratios after liver transplantation suggests an important role of MI and Cho in the development of hepatic encephalopathy.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Encéfalo/metabolismo , Metabolismo Energético/fisiologia , Encefalopatia Hepática/metabolismo , Transplante de Fígado , Espectroscopia de Ressonância Magnética , Ácido Aspártico/análise , Ácido Aspártico/análogos & derivados , Estudos de Casos e Controles , Colina/análise , Creatina/análise , Creatina/biossíntese , Encefalopatia Hepática/cirurgia , Inositol/análise , Estudos Prospectivos
20.
Rev. bras. eng. biomed ; 24(2): 131-137, ago. 2008. tab, graf
Artigo em Inglês | LILACS | ID: lil-576309

RESUMO

In this research we obtained samples of human respiratory flow, oxygen concentration and carbon dioxide concentration signals from 20 healthy subjects and evaluated the average power spectral density (PSD) of these signals. For each subject,the respiratory samples were acquired in four progressive levels of exercise in a cycle ergometer. Auto regressive moving average models were designed to represent the PSD found in each phase. An average PSD of the four levels was also calculated. Results have shown that the bandwidth of O2 concentration, CO2 concentration and flow signals was 8  Hz, 7 Hz, and 15  Hz, respectively, within the dynamic range of 50  dB. The PSD curves found can be used for optimal filter design for signal enhancing in fast on-line measurement of these signals.


Nesta pesquisa foram registradas amostras dos sinais respiratórios de fluxo, concentração de oxigênio e concentração de gás carbônico em 20 voluntários saudáveis. A densidade espectral de potência (DEP) média foi então calculada. Para cada voluntário, as amostras dos sinais foram registradas em quatro intensidades progressivas de esforço físico em uma bicicleta ergométrica. Para representar a DEP encontrada em cada fase foram ajustados modelos auto-regressivos de média móvel. Uma DEP média entre as quatro intensidades também é fornecida. Os resultados mostraram que as larguras de banda dos sinais de concentração de O2, concentração de CO2 e fluxo foram 8  Hz, 7  Hz e 15  Hz, respectivamente, dentro de uma faixa dinâmica de 50  dB. As curvas de DEP encontradas podem ser usadas em projetos de filtros ótimos para equalização destes sinais em medições em tempo real.


Assuntos
Humanos , Masculino , Feminino , Análise Espectral/métodos , Espirometria/métodos , Teste de Esforço , Testes de Função Respiratória/métodos , Dióxido de Carbono/análise , Fluxo Expiratório Forçado , Volume Expiratório Forçado , Gasometria/métodos , Curvas de Fluxo-Volume Expiratório Máximo , Mecânica Respiratória/fisiologia , Nível de Oxigênio/análise , Pico do Fluxo Expiratório
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...